LOW STATIC PRESSURE DUCT
CNT3-3-XY D15÷D112
  • COMPACT DESIGN

All models in the series are 199 mm high and 450 mm deep, requiring minimal installation space.

  • CONSTANT AIR FLOW

Thanks to the use of a digitally controlled fan, the air flow rate can be kept constant. Furthermore, it is possible to have an estimate of the percentage of clogging of the filters on the wired controls.

  • ADJUSTABLE STATIC PRESSURE

To adapt to installation conditions, the head of the unit can be precisely set between 10 and 50 or 80Pa depending on the size.

  • HIGH HEAD DRAINAGE PUMP

The condensate drain pump is included and can overcome a head of up to 1200 mm water column.

  • HIGH-EFFICIENCY EXCHANGER

Thanks to the exchanger's C-shaped design, a large heat exchange area can be achieved with a small footprint.

MEDIUM STATIC PRESSURE DUCT
CNT2-3-XY D15-D56
  • COMPACT DESIGN

All models are now 245 mm high, making them easy to position in the ceiling.

  • HIGH-LIFT DRAIN PUMP

A drain pump with a 1200 mm pump head is fitted as standard, simplifying installation of the drain piping.

  • HIGH FLEXIBILITY

To provide the flexibility to adapt to differing installation situations, the air inlet may be positioned either on the underside or the rear of the unit.

  • CONSTANT AIR FLOW OVER TIME

Thanks to the use of a digitally controlled fan, the air flow rate can be kept constant. In addition, an estimate of the filter clogging percentage is indicated on the controls.

  • STATIC PRESSURE 10 STEPS CONTROL

Depending on the installation conditions, the head of the unit can be precisely set between 10 and 160Pa, choosing from 20 different combinations

HIGH STATIC PRESSURE DUCT
CN-3-XY D56-D560
  • FLEXIBLE DUCT DESIGN

The High Static Pressure Duct indoor unit offers external static pressures of up to 400 Pa, allowing the use of long ducts. With a height of just 299 mm (units D56 to D160),  can be used in most installation situations.

  • CONSTANT AIR FLOW RATE

Thanks to the use of a digitally controlled fan, the air flow rate can be kept constant. In addition, an estimate of the filter clogging percentage is indicated on the controls.

  • HIGH HEAD DRAINAGE PUMP

The condensate drain pump is included and can overcome a head of up to 1200 mm water column.

  • STATIC PRESSURE WITH 20 STEPS CONTROL

Depending on the installation environment, units can be precisely set up to 20 steps of static pressure/airflow rate combinations via wired remote controller, providing comfortable environment suitable for any application.

FRESH AIR PROCESSING UNIT
CNFA-3-XY D90-D160
  • 100% FRESH AIR PROCESSING UNIT

Both fresh air filtration and heating/cooling can be achieved in a single system.
Indoor units and the Fresh Air Processing Unit can be connected to the same refrigerant system, increasing design flexibility and greatly reducing total system costs.

  • FLEXIBLE DUCT DESIGN

The Fresh Air Processing unit offers external static pressures of up to 300Pa, allowing the use of long ducts.

  • THE COMFORT OF FRESH AIR

Enjoy the comfort and health benefits of fresh air being drawn into your working or living environment.

  • STATIC PRESSURE WITH 20 STEPS CONTROL

Depending on the installation environment, units can be precisely set up to 20 steps of static pressure/airflow rate combinations via wired remote controller, providing comfortable environment suitable for any application.

  • SUPPLY AIR TEMPERATURE CONTROL

While other VRF indoor units control the return air temperature as set point, the fresh air processing unit controls the supply air temperature as set point, in order to more precisely manage the outdoor fresh air and release it indoor.

Portlet not configured, please configure